The Fire-Lite ANN-80 is a remote fire annunciator with an 80-character LCD display, designed to provide real-time status updates and enhance fire alarm system visibility.
Overview of the ANN-80 Series
The Fire-Lite ANN-80 Series is a line of remote fire annunciators designed for compatibility with Fire-Lite fire alarm control panels (FACP). These devices feature an 80-character backlit LCD display, providing clear status updates and system information.
Compact and versatile, the ANN-80 Series is ideal for installations requiring remote monitoring of fire alarm systems. It supports ANN-BUS communication, enabling seamless integration with compatible Fire-Lite systems for enhanced functionality and reliability.
Key Features and Benefits
The Fire-Lite ANN-80 Series offers a backlit 80-character LCD display for clear status updates. It supports ANN-BUS communication, ensuring compatibility with Fire-Lite FACPs. Unique addressing via DIP switches simplifies installation. The compact design allows for versatile mounting options. Power cycling and reset features aid in troubleshooting. These features enhance system visibility, reliability, and user experience, making the ANN-80 Series a robust choice for fire alarm monitoring.
Installation Requirements and Setup
Ensure proper mounting and wiring, with the cover attached during installation. Follow pre-installation checklists for compatibility and power requirements to ensure seamless setup and functionality.
Pre-Installation Checklist
Before installing the ANN-80, ensure compatibility with your FACP. Verify operating voltage (18-28 VDC) and current requirements; Check ANN-BUS addressing and DIP switch settings. Ensure all necessary hardware and tools are available. Review the user manual for specific instructions and safety precautions to ensure a smooth and successful installation process.
MOUNTING THE ANN-80 SERIES
The ANN-80 Series must be mounted on a standard electrical box or wall. Attach the backplate to the electrical box using the provided screws. Ensure the cover remains attached during installation to prevent damage. If using a wall bracket, secure it to the wall first. Mount the annunciator flush to the wall for proper alignment. Tighten all screws firmly to ensure stability and proper operation.
Initial Setup and Configuration
Begin by turning the key switch to the ‘ON’ position to unlock the cover. Set the DIP switches according to the system requirements to configure the ANN-BUS address. Ensure the device is properly powered and connected to the FACP. Verify compatibility with the fire alarm control panel and perform a system test to confirm proper communication. Refer to the manual for specific address settings and configuration details to ensure optimal performance.
Wiring and Connectivity
Ensure proper wiring connections between the ANN-80 and FACP, referencing the manual for specific instructions. Set DIP switches to configure the ANN-BUS address correctly for system compatibility.
Wiring the ANN-80 Series to the FACP
Refer to Table 1 and Figure 3 for detailed wiring connections. Each ANN-BUS device requires a unique address set via DIP switch S21. This address appears on the LCD as the ANN-80 Series FACP ANN-BUS Station ID. Ensure proper wiring to the FACP, following the manual’s instructions for compatibility and functionality. Correct wiring ensures seamless communication between the ANN-80 and the fire alarm control panel, maintaining system integrity and performance.
Setting the DIP Switches
The ANN-80 Series uses DIP switches to configure settings, with S21 specifically setting the ANN-BUS address. Each device requires a unique address, ensuring proper communication with the FACP. Refer to the manual for switch configurations, as incorrect settings may cause connectivity issues. The address set via S21 appears on the LCD as the ANN-BUS Station ID, confirming correct configuration for seamless system operation and functionality.
Troubleshooting Wiring Issues
Ensure all connections are secure and match the wiring diagram in the manual. Verify ANN-BUS devices have unique addresses. If issues persist, power cycle the panel by turning it off, waiting a few minutes, and restarting. Consult the ANN-80 user manual for specific troubleshooting steps or contact Fire-Lite technical support for further assistance to resolve connectivity or communication problems effectively.
Programming the ANN-80 Annunciator
Programming the ANN-80 involves setting DIP switches for unique addressing and synchronizing with the FACP for seamless operation.
Configuring the ANN-BUS Address
To configure the ANN-BUS address, use DIP switch S21 on the ANN-80 Series. Each device requires a unique address, displayed on the LCD as the Station ID number. Ensure the address matches the FACP settings for proper communication. Refer to the user manual for detailed instructions. Incorrect settings may cause communication issues, so double-check configurations before finalizing. If issues arise, consult the manual or contact Fire-Lite support for assistance.
Programming the Annunciator for Device Compatibility
Programming the ANN-80 Annunciator ensures compatibility with Fire-Lite systems like the MS-9600 and MS-9200UDLS panels. Use the DIP switches to set the ANN-BUS address, ensuring each device has a unique ID. Refer to the user manual for specific instructions on configuring compatibility settings. Proper synchronization with the FACP is crucial for accurate system operation. If issues arise, power cycling the panel or consulting the manual can resolve most connectivity problems.
Synchronizing the Annunciator with the FACP
Synchronizing the ANN-80 with the Fire Alarm Control Panel (FACP) ensures both devices display consistent information; Set the ANN-BUS address using DIP switches to match the FACP configuration. Refer to the user manual for detailed synchronization steps. Proper synchronization prevents mismatched displays and ensures accurate system status updates. If issues arise, power cycling the panel or consulting the manual can help restore proper communication between the ANN-80 and FACP.
Troubleshooting Common Issues
Common issues with the ANN-80 include synchronization problems, display malfunctions, or communication errors. Power cycling or resetting the device often resolves these issues. Consult the manual for detailed troubleshooting steps and solutions to ensure proper functionality.
Common Problems and Solutions
Common issues with the ANN-80 include synchronization problems, display malfunctions, or communication errors. Power cycling the device often resolves these issues. If the annunciator fails to display correct information, check the ANN-BUS connections and ensure all DIP switches are properly set. For persistent display issues, reset the device or update its firmware. Refer to the user manual for detailed troubleshooting steps and solutions to restore proper functionality.
- Synchronization issues: Restart the device and ensure proper ANN-BUS connections.
- Display malfunctions: Verify wiring and reset the device if necessary.
- Communication errors: Check DIP switch settings and ensure unique ANN-BUS addresses.
Power Cycling and Reset Procedures
To reset the ANN-80, turn off the power at the FACP, wait 30 seconds, and restore power. For a soft reset, this cycle often resolves minor issues. If the device still malfunctions, perform a hard reset by pressing and holding the navigation buttons while powering on. This restores factory settings. Always consult the user manual for detailed reset procedures and ensure proper system synchronization post-reset.
- Power cycle: Turn off, wait, and restore power to reset.
- Soft reset: Clears temporary issues without losing configurations.
- Hard reset: Restores factory settings for severe malfunctions.
Maintenance and Upkeep
Regularly clean the ANN-80’s LCD display with a soft cloth and mild detergent to maintain visibility. Inspect wiring connections for damage or corrosion. Schedule annual inspections to ensure proper functionality and address potential issues early.
Cleaning and Care Instructions
Regular cleaning of the ANN-80 annunciator is essential for optimal performance. Use a soft, dry cloth to wipe down the exterior and LCD display. For stubborn marks, dampen the cloth with a mild detergent solution, but avoid harsh chemicals or abrasive materials. Never spray liquids directly on the device. Power down the unit before cleaning to prevent damage. Avoid exposing the annunciator to extreme temperatures or humidity.
Software and Firmware Updates
Regular software and firmware updates ensure the ANN-80 operates at peak performance. Always refer to the user manual for specific instructions on updating the device. Power cycling the panel may be required during or after the update process. If issues arise, consult the manual or contact Fire-Lite technical support for assistance. Keeping the firmware updated guarantees compatibility with Fire-Lite systems and maintains reliable operation.
Technical Specifications
The Fire-Lite ANN-80 operates within 18-28 VDC, consumes 24 VDC nominal current, and is compatible with Fire-Lite systems, featuring an 80-character LCD display.
Operating Voltage and Current Requirements
The Fire-Lite ANN-80 operates on a voltage range of 18 VDC to 28 VDC, with a nominal current consumption of 24 VDC. This ensures compatibility with most fire alarm systems. The unit requires a filtered and non-resettable power supply to maintain stable operation. Engineers and installers should verify these specifications to ensure proper integration with Fire-Lite control panels and maintain optimal performance.
Compatibility with Fire-Lite Systems
The ANN-80 is fully compatible with Fire-Lite’s MS-9600 and MS-9200UDLS fire alarm control panels. It seamlessly integrates with these systems, ensuring reliable communication and accurate status reporting. The ANN-80’s design allows it to mimic the FACP display, providing consistent and unified system monitoring. This compatibility ensures a cohesive fire alarm network, enhancing overall system performance and user confidence in emergency situations.
Compatibility with Fire-Lite Systems
The Fire-Lite ANN-80 is compatible with Fire-Lite’s MS-9600 and MS-9200UDLS fire alarm control panels, ensuring seamless integration and reliable communication for enhanced system monitoring and control.
Compatible Fire Alarm Control Panels
The Fire-Lite ANN-80 is designed to work seamlessly with the MS-9600 and MS-9200UDLS fire alarm control panels. These panels provide advanced monitoring and control capabilities, ensuring reliable performance and integration with the ANN-80’s features. Compatibility ensures real-time communication, enabling comprehensive system oversight and efficient response to alarms. Proper setup with these panels is essential for optimal functionality.
User Manual and Documentation
The Fire-Lite ANN-80 user manual provides comprehensive guidance on installation, operation, and maintenance. It includes detailed instructions, diagrams, and troubleshooting tips, ensuring seamless setup and optimal performance.
What’s Included in the User Manual
The Fire-Lite ANN-80 user manual includes detailed installation instructions, wiring diagrams, configuration steps, and troubleshooting guides. It also covers system specifications, maintenance tips, and technical support information, ensuring a comprehensive resource for installers and users to maximize the annunciator’s functionality and performance.
Additional Resources and Support
Fire-Lite offers extensive technical support, including online resources, troubleshooting guides, and video tutorials. Users can access the ANN-80 Series User Manual and documentation through the Fire-Lite website. Additionally, dedicated customer service and expert technical assistance are available to address installation, configuration, and operational queries, ensuring seamless integration and optimal performance of the ANN-80 annunciator.
Best Practices for Optimal Performance
Regularly update firmware, ensure proper wiring, and power cycle when issues arise. Refer to the manual for specific guidance and troubleshooting tips to maintain functionality.
Installer and User Tips
For optimal performance, ensure correct ANN-BUS addressing and proper wiring connections. Power cycle the panel if issues arise, and refer to the manual for troubleshooting. Regular firmware updates are essential. Use Fire-Lite technical support for complex configurations. Always verify DIP switch settings before initial setup. Keep the LCD display clean for clear visibility. Ensure compatibility with your FACP to avoid communication errors. Follow all safety guidelines during installation and maintenance.
The Fire-Lite ANN-80 Annunciator is a robust and user-friendly solution for fire alarm systems, offering clear LCD display, compatibility with FACPs, and easy troubleshooting. Regular maintenance and firmware updates ensure optimal performance. Refer to the manual for detailed guidance, and consult Fire-Lite support for advanced configurations. Adherence to installation and operational guidelines guarantees reliability and compliance with safety standards, making the ANN-80 a reliable choice for fire safety systems.